The system deployment consists of two parts: Hardware (equipment) and software. SEHO has extensive experience and expertise in the technology and equipment, so the system installation is not complex.
SEHO uses modern equipment from reputable manufacturers, ensuring high accuracy that meets meteorological and hydrological monitoring standards in Vietnam:
1. Rainfall measurement: ± 3.5% (Vietnamese standards: ± 0.4 mm for rainfall ≤ 10 mm, ± 4% for rainfall > 10 mm).
2. Water level: ± 2 mm (Vietnamese standards: ± 1 cm).
1. Rainfall measurement: According to Circular 13/2023/TT-BTNMT, "The density of rainfall measurement stations in the catchment area should be less than or equal to 100 km² per station; the distance between two adjacent stations should not exceed 15 km," so the number of stations will be specified based on the catchment area of the hydroelectric plant.
2. Water level and flow measurement: Depending on the needs of each hydroelectric plant, there is no specific regulation.